Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Biosci. j. (Online) ; 37: e37012, Jan.-Dec. 2021. ilus, graf, tab
Article in English | LILACS | ID: biblio-1358679

ABSTRACT

The objective was to evaluate weed phytosociology and similarities between crop management systems in the Chapadões region. The experiment was conducted at in agricultural area located in the municipality of Chapadão do Sul, MS, during the 2016/17 harvest. Three crop managements strategies were used: (1) cotton/soybean/Urochloa, (2) millet/soybean/millet and (3) millet/soybean/crotalaria. A phytosociological survey of weeds was carried out during soybean cultivation and cover crops growth, in succession. The evaluation area for each management strategy was 0.5 ha. Soybean surveys were carried out in October and January, while the cover crop surveys were performed in February and May. The relative frequency (RF), relative density (RD), relative abundance (AR), and relative importance (RI) of weeds, Venn diagram, and Jaccard and Sorenson similarity indices were evaluated. The management area represented by the cotton/soybean/Urochloa rotation had fewer weed species than others. The species Cenchrus echinatus, Digitaria insularis, Digitaria sanguinalis, Eleusine indica and Commelina benghalensis had the highest phytosociological indeces among the monocotyledons. Attention is required for managing the dicotyledons Amaranthus deflexus, Conyza canadensis and Senna obtusifolia despite their low indices because of herbicide resistant cases. The highest indeces of similarity were found between managements areas 2 and 3, which did not rely on cotton cultivation prior to soybeans.


Subject(s)
Culture Techniques , Plant Weeds/classification
2.
Eng. sanit. ambient ; 22(1): 145-153, jan.-fev. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-840379

ABSTRACT

RESUMO O dimensionamento econômico ótimo de redes de distribuição de água tem sido objeto de estudo de diversos pesquisadores e projetistas, e representa uma relevante parte nas ações de saneamento básico. No entanto, até então, aborda-se somente o custo de implantação, considerando que o custo dos condutos é um dos elementos de maior peso no projeto. Assim, o problema resume-se a dimensionar os condutos tendo como objetivo atingir uma rede de menor custo e que satisfaça os pré-requisitos hidráulicos mínimos de dimensionamento. Isso conduz necessariamente à escolha de uma rede cuja combinação de condutos de menor diâmetro possível e que também seja capaz de satisfazer as restrições hidráulicas. Nossa abordagem, inédita até agora no Brasil, considera, adicionalmente, o custo de manutenção ao longo da vida útil da rede, tendo em vista que, se por um lado os condutos de maior diâmetro são mais caros, por outro lado, sofrem menos os efeitos da rugosidade e apresentam uma frequência menor de manutenção que os condutos de menor diâmetro, levando, assim, a uma rede que, ao longo da vida útil do projeto, apresenta um custo menor. Assim, obtém-se um equilíbrio entre o custo de implantação e o custo de manutenção da rede.


ABSTRACT The optimum economic sizing of a water distribution network has been focus of study for many researches and projectors, and represent a relevant part of sanitation programs. But, by now, the known works approaches only the implantation cost, considering that the pipes have biggest heavy in the project. So, the problem is reduced to sizing pipes which objective is reach a cheaper network and satisfying the minimum hydraulic prerequisites. This leads to the choice of a network with pipes of minor diameters since this choice satisfies the hydraulics restrictions. New in Brazil by now, our approach consider too the maintenance cost throughout life span of network. It because, if in one way the larger diameters are more expensive, in an other, it are more resistant to break and to rugosity effects. This leads to a network of minimum maintenance cost throughout its life span. Then, we reach the equilibrium between the implantation cost and the maintenance cost.

3.
Eng. sanit. ambient ; 19(1): 11-22, Jan-Mar/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-703063

ABSTRACT

O presente trabalho apresenta resultados de estudos analítico-experimentais visando à verificação das condições de estanqueidade de bacias de contenção de tanques de armazenamento de combustíveis de um terminal portuário situado no Nordeste brasileiro. Com esse objetivo, foi efetuado estudo de caso com foco na avaliação da vulnerabilidade ambiental de duas áreas de estocagem distintas, para as quais foi realizada uma simulação transiente do avanço da frente de contaminação em um cenário hipotético de grande derramamento acidental de combustível em um terreno não saturado. Para o desenvolvimento dos estudos, procedeu-se à realização de uma extensa campanha de investigações geotécnicas de campo e de laboratório e à realização de simulações numéricas de fluxo multifásico, com o emprego do método dos elementos finitos.


This work presents results of analytical and experimental studies concerning the evaluation of permeability conditions of spill diversion ponds around fuel storage tanks located in a Brazilian northeast industrial plant. For this purpose, a case study was carried out in order to assess the environmental vulnerability of two distinct storage areas, by means of transient numerical simulations of contaminant advance in unsaturated soil after a hypothetical accident with hydrocarbon spill. For the development of the study, extensive geotechnical field and laboratory investigations were carried out, and numerical multiphase flow simulations were accomplished with the use of the finite element method.

4.
Eng. sanit. ambient ; 15(2): 187-196, jun. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-561323

ABSTRACT

A operação dos Sistemas de Abastecimento de Água é realizada por profissionais que usam a sua experiência como um meio de avaliação no controle de equipamentos hidromecânicos com o objetivo de garantir o fornecimento de água à população. Geralmente, as regras operacionais utilizadas visam à garantia da continuidade do abastecimento público, sem a preocupação com a economia de energia elétrica dos motores em funcionamento. Neste trabalho, apresenta-se um algoritmo genético híbrido que permite determinar as estratégias de operações com custos energéticos reduzidos. A análise do modelo é feita em um estudo de caso real localizado na cidade de Ourém (Portugal). O novo modelo reduz consideravelmente o tempo computacional em comparação aos modelos utilizados na literatura especializada.


The operation of water supply systems is normally done by professionals who use their experience as the sole source of knowledge in order to establish rules to control the daily operation of hydro-mechanical equipments aiming at the guarantee of an adequate performance of the system. In general, these rules have as main goal the assurance of the water demands of the population and do not take into account optimization of the electrical energy consumed by the pumps. This work proposes a new hybrid genetic algorithm. The main purpose of this code is to determine optimized system operational rules with regard to saving electrical energy consumed by the pumps. The code was tested using one real water supply system localized in Ourém city (Portugal). The results showed considerable decrease in computational time as comparing to other codes available.

5.
Eng. sanit. ambient ; 10(3): 229-235, jul.-set. 2005. tab, graf
Article in Portuguese | LILACS | ID: lil-415873

ABSTRACT

A determinação da quantidade de percolado gerado em aterros sanitários continua sendo uma tarefa difícil, principalmente no semi-árido nordestino onde predominam caracteríticas meteorológicas e geológicas bem peculiares. O programa HELP (avaliação do comportamento hidrológico em aterros sanitários), desenvolvido por Schroder et al (1984), foi utilizado na simulação de várias configurações de drenagem de fundo. Aplicou-se ao modelo, dados meteorológicos e de solos da região onde está o aterro sanitário de Caucaia (ASMOC), a qual é representativa do semi-árido nordestino. Três características da drenagem de fundo foram variadas (configuração da drenagem, inclinação de fundo e adição de uma camada drenante com alta permeabilidade) com o objetivo de avaliar a altura da coluna de percolado, a quantidade de percolado infiltrado no solo e o volume coletado para tratamento. Nas trincheiras sem camada drenante, o aumento da inclinação de fundo e a alteração da configuração dos drenos tiveram pouca influência sobre as variáveis estudadas. A adição da camada drenante proporcionou uma redução significativa da altura da coluna e na infiltração de percolado no solo, mostrando que é um componente fundamental para o bom funcionamento do sistema de drenagem horizontal em aterros sanitários.


Subject(s)
Domestic Wastes , Drainage, Sanitary , Percolating Liquid , Sanitary Landfill , Water Pollution , Groundwater , Hydrology , Surface Waters
6.
GED gastroenterol. endosc. dig ; 20(6): 225-229, nov.-dez. 2001. ilus
Article in English | LILACS | ID: lil-324845

ABSTRACT

Hamartoma biliar único e volumoso é uma lesäo relativamente rara. Descreve-se o caso de uma lesäo de aproximadamente 5cm, localizada no segmento IV do fígado, sem outras alterações aparentes. Essa lesäo foi estudada por métodos de imagem, laparoscopia e biópsia. O tratamento é discutido, especialmente considerando o risco de malignizaçäo, com revisäo da literatura


Subject(s)
Humans , Female , Adult , Hamartoma , Biopsy , Diagnostic Imaging , Laparoscopy
SELECTION OF CITATIONS
SEARCH DETAIL